Temporal acuity is the ability to differentiate between sounds based on fluctuations in the waveform envelope. The proximity of successive sounds and background noise diminishes the ability to track rapid changes between consecutive sounds. We determined whether a physiological correlate of temporal acuity is also affected by these factors. We recorded the auditory brainstem response (ABR) from human listeners using a harmonic complex (S1) followed by a brief tone burst (S2) with the latter serving as the evoking signal. The duration and depth of the silent gap between S1 and S2 were manipulated, and the peak latency and amplitude of wave V were measured. The latency of the responses decreased significantly as the duration or depth of the gap increased. The amplitude of the responses was not affected by the duration or depth of the gap. These findings suggest that changing the physical parameters of the gap affects the auditory system’s ability to encode successive sounds.
| Original language | English |
|---|---|
| Pages (from-to) | 38-46 |
| Number of pages | 9 |
| Journal | Audiology Research |
| Volume | 11 |
| Issue number | 1 |
| DOIs | |
| State | Published - Mar 2021 |
Keywords
- Auditory evoked potentials
- Gap depth
- Gap duration
- Successive sounds
- Temporal processing