Deltoid electromyography is reliable during submaximal isometric ramp contractions

David Phillips, Andrew Karduna

Research output: Contribution to journalArticleResearchpeer-review

2 Citations (Scopus)

Abstract

The EMG and load relationship is commonly measured with multiple submaximal isometric contractions. This method is both time consuming and may introduce fatigue. The purpose of this study was to determine if the electromyography (EMG) amplitude from the middle deltoid was reliable during isometric ramp contractions (IRCs) at different angles of elevation and rates of force application. Surface EMG was measured at 3 shoulder elevation angles during IRCs at 4 submaximal levels of maximum voluntary contraction (MVC). Data were reliable in all conditions except during the rate relative to the subjects' MVC at 90° for 30% and 40% MVC. The main effect for angle on EMG amplitude was found to be significant, p < .01. EMG at 90° was greater than at 60° (p < .017) and at 30° (p < .017). The main effect of force level on EMG amplitude was significant, p < .01 and follow-up contrast demonstrated a significant (p < .001) linear increase of EMG amplitude with force level. We conclude that EMG amplitude from IRCs are reliable across all shoulder elevation angles and up to 40% MVC. IRCs are a feasible method for recording EMG at the deltoid.

Original languageEnglish
Pages (from-to)237-240
Number of pages4
JournalJournal of Applied Biomechanics
Volume33
Issue number3
DOIs
StatePublished - 1 Jun 2017

Fingerprint

Architectural Accessibility
Isometric Contraction
Electromyography
Fatigue

Keywords

  • Contraction
  • Deltoid
  • EMG
  • Ramp
  • Reliability
  • Shoulder

Cite this

@article{26e4b6ab2540420da33a0e18d72c17d6,
title = "Deltoid electromyography is reliable during submaximal isometric ramp contractions",
abstract = "The EMG and load relationship is commonly measured with multiple submaximal isometric contractions. This method is both time consuming and may introduce fatigue. The purpose of this study was to determine if the electromyography (EMG) amplitude from the middle deltoid was reliable during isometric ramp contractions (IRCs) at different angles of elevation and rates of force application. Surface EMG was measured at 3 shoulder elevation angles during IRCs at 4 submaximal levels of maximum voluntary contraction (MVC). Data were reliable in all conditions except during the rate relative to the subjects' MVC at 90° for 30{\%} and 40{\%} MVC. The main effect for angle on EMG amplitude was found to be significant, p < .01. EMG at 90° was greater than at 60° (p < .017) and at 30° (p < .017). The main effect of force level on EMG amplitude was significant, p < .01 and follow-up contrast demonstrated a significant (p < .001) linear increase of EMG amplitude with force level. We conclude that EMG amplitude from IRCs are reliable across all shoulder elevation angles and up to 40{\%} MVC. IRCs are a feasible method for recording EMG at the deltoid.",
keywords = "Contraction, Deltoid, EMG, Ramp, Reliability, Shoulder",
author = "David Phillips and Andrew Karduna",
year = "2017",
month = "6",
day = "1",
doi = "10.1123/jab.2016-0224",
language = "English",
volume = "33",
pages = "237--240",
journal = "Journal of Applied Biomechanics",
issn = "1065-8483",
publisher = "Human Kinetics Publishers Inc.",
number = "3",

}

Deltoid electromyography is reliable during submaximal isometric ramp contractions. / Phillips, David; Karduna, Andrew.

In: Journal of Applied Biomechanics, Vol. 33, No. 3, 01.06.2017, p. 237-240.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - Deltoid electromyography is reliable during submaximal isometric ramp contractions

AU - Phillips, David

AU - Karduna, Andrew

PY - 2017/6/1

Y1 - 2017/6/1

N2 - The EMG and load relationship is commonly measured with multiple submaximal isometric contractions. This method is both time consuming and may introduce fatigue. The purpose of this study was to determine if the electromyography (EMG) amplitude from the middle deltoid was reliable during isometric ramp contractions (IRCs) at different angles of elevation and rates of force application. Surface EMG was measured at 3 shoulder elevation angles during IRCs at 4 submaximal levels of maximum voluntary contraction (MVC). Data were reliable in all conditions except during the rate relative to the subjects' MVC at 90° for 30% and 40% MVC. The main effect for angle on EMG amplitude was found to be significant, p < .01. EMG at 90° was greater than at 60° (p < .017) and at 30° (p < .017). The main effect of force level on EMG amplitude was significant, p < .01 and follow-up contrast demonstrated a significant (p < .001) linear increase of EMG amplitude with force level. We conclude that EMG amplitude from IRCs are reliable across all shoulder elevation angles and up to 40% MVC. IRCs are a feasible method for recording EMG at the deltoid.

AB - The EMG and load relationship is commonly measured with multiple submaximal isometric contractions. This method is both time consuming and may introduce fatigue. The purpose of this study was to determine if the electromyography (EMG) amplitude from the middle deltoid was reliable during isometric ramp contractions (IRCs) at different angles of elevation and rates of force application. Surface EMG was measured at 3 shoulder elevation angles during IRCs at 4 submaximal levels of maximum voluntary contraction (MVC). Data were reliable in all conditions except during the rate relative to the subjects' MVC at 90° for 30% and 40% MVC. The main effect for angle on EMG amplitude was found to be significant, p < .01. EMG at 90° was greater than at 60° (p < .017) and at 30° (p < .017). The main effect of force level on EMG amplitude was significant, p < .01 and follow-up contrast demonstrated a significant (p < .001) linear increase of EMG amplitude with force level. We conclude that EMG amplitude from IRCs are reliable across all shoulder elevation angles and up to 40% MVC. IRCs are a feasible method for recording EMG at the deltoid.

KW - Contraction

KW - Deltoid

KW - EMG

KW - Ramp

KW - Reliability

KW - Shoulder

UR - http://www.scopus.com/inward/record.url?scp=85027011995&partnerID=8YFLogxK

U2 - 10.1123/jab.2016-0224

DO - 10.1123/jab.2016-0224

M3 - Article

VL - 33

SP - 237

EP - 240

JO - Journal of Applied Biomechanics

JF - Journal of Applied Biomechanics

SN - 1065-8483

IS - 3

ER -