Detection and interaural time discrimination of a sinusoid masked by interaurally delayed white noise

Marion F. Cohen, Janet Koehnke

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Masking-level differences and masked interaural time jnds were measured for a 560- and a 1000-Hz tone-burst signal. The masker, a diotic white noise, was interaurally time delayed by amounts ranging from no delay to one full period of the signal frequency. Results show that the size of the jnd varies systematically with the masking-level difference. Those masker delays which most benefit detection cause poorer signal interaural time discrimination.

Original languageEnglish
Pages (from-to)1418-1420
Number of pages3
JournalJournal of the Acoustical Society of America
Volume72
Issue number5
DOIs
StatePublished - Nov 1982

Keywords

  • 43.66. Dc
  • 43.66. Mk [JH]
  • 43.66. Rq
  • PACS numbers

Fingerprint

Dive into the research topics of 'Detection and interaural time discrimination of a sinusoid masked by interaurally delayed white noise'. Together they form a unique fingerprint.