The accuracy of subacromial corticosteroid injections: A comparison of multiple methods

Michael N. Kang, Louis Rizio, Michael Prybicien, David Middlemas, Marcia F. Blacksin

Research output: Contribution to journalArticle

52 Citations (Scopus)

Abstract

Corticosteroids are commonly used in the treatment of the impingement syndrome. Efficacy, as well as accurate placement, have been questioned. The purpose of this prospective, randomized study is to assess the accuracy of subacromial injections and to correlate accuracy with short term clinical outcome at 3 months. Sixty shoulders, which were diagnosed with impingement syndrome, were randomized to receive a subacromial injection of corticosteroids, local anesthetic, and contrast dye from 1 of 3 locations: anterolateral, lateral, or posterior. Accuracy was confirmed by 3 radiographic views of the shoulder, while clinical ratings were assessed by the UCLA shoulder score and a 10-point visual pain analog scale during the initial, post-injection, and 3-month visits. The overall accuracy was 70%, with no difference among the 3 portals. Accuracy was not related to body mass index. Furthermore, accurate injections did not significantly improve the UCLA score, pain scale, or patient satisfaction at 3 months. In contrast, accurate injections produced a positive Neer's impingement test more often (35/39 vs 9/16; P = .009). Overall, there was an improvement in the UCLA score (26.2-32.2; P < .001) and a decrease in the pain scale (7.2-3.43; P < .001) at 3-month follow-up. In conclusion, the accuracy of injection was 70%. Clinical improvement did not correlate with accuracy; however, accuracy did reliably produce a positive impingement test. This multimodal treatment plan did produce significant improvement in shoulder function and pain level in the short term.

Original languageEnglish
JournalJournal of Shoulder and Elbow Surgery
Volume17
Issue number1 SUPPL.
DOIs
StatePublished - 1 Jan 2008

Fingerprint

Adrenal Cortex Hormones
Injections
Pain
Combined Modality Therapy
Shoulder Pain
Pain Measurement
Local Anesthetics
Patient Satisfaction
Body Mass Index
Coloring Agents
Prospective Studies
Therapeutics

Cite this

Kang, Michael N. ; Rizio, Louis ; Prybicien, Michael ; Middlemas, David ; Blacksin, Marcia F. / The accuracy of subacromial corticosteroid injections : A comparison of multiple methods. In: Journal of Shoulder and Elbow Surgery. 2008 ; Vol. 17, No. 1 SUPPL.
@article{ef40a88c48fb4b94a147cca032651283,
title = "The accuracy of subacromial corticosteroid injections: A comparison of multiple methods",
abstract = "Corticosteroids are commonly used in the treatment of the impingement syndrome. Efficacy, as well as accurate placement, have been questioned. The purpose of this prospective, randomized study is to assess the accuracy of subacromial injections and to correlate accuracy with short term clinical outcome at 3 months. Sixty shoulders, which were diagnosed with impingement syndrome, were randomized to receive a subacromial injection of corticosteroids, local anesthetic, and contrast dye from 1 of 3 locations: anterolateral, lateral, or posterior. Accuracy was confirmed by 3 radiographic views of the shoulder, while clinical ratings were assessed by the UCLA shoulder score and a 10-point visual pain analog scale during the initial, post-injection, and 3-month visits. The overall accuracy was 70{\%}, with no difference among the 3 portals. Accuracy was not related to body mass index. Furthermore, accurate injections did not significantly improve the UCLA score, pain scale, or patient satisfaction at 3 months. In contrast, accurate injections produced a positive Neer's impingement test more often (35/39 vs 9/16; P = .009). Overall, there was an improvement in the UCLA score (26.2-32.2; P < .001) and a decrease in the pain scale (7.2-3.43; P < .001) at 3-month follow-up. In conclusion, the accuracy of injection was 70{\%}. Clinical improvement did not correlate with accuracy; however, accuracy did reliably produce a positive impingement test. This multimodal treatment plan did produce significant improvement in shoulder function and pain level in the short term.",
author = "Kang, {Michael N.} and Louis Rizio and Michael Prybicien and David Middlemas and Blacksin, {Marcia F.}",
year = "2008",
month = "1",
day = "1",
doi = "10.1016/j.jse.2007.07.010",
language = "English",
volume = "17",
journal = "Journal of Shoulder and Elbow Surgery",
issn = "1058-2746",
publisher = "Mosby Inc.",
number = "1 SUPPL.",

}

The accuracy of subacromial corticosteroid injections : A comparison of multiple methods. / Kang, Michael N.; Rizio, Louis; Prybicien, Michael; Middlemas, David; Blacksin, Marcia F.

In: Journal of Shoulder and Elbow Surgery, Vol. 17, No. 1 SUPPL., 01.01.2008.

Research output: Contribution to journalArticle

TY - JOUR

T1 - The accuracy of subacromial corticosteroid injections

T2 - A comparison of multiple methods

AU - Kang, Michael N.

AU - Rizio, Louis

AU - Prybicien, Michael

AU - Middlemas, David

AU - Blacksin, Marcia F.

PY - 2008/1/1

Y1 - 2008/1/1

N2 - Corticosteroids are commonly used in the treatment of the impingement syndrome. Efficacy, as well as accurate placement, have been questioned. The purpose of this prospective, randomized study is to assess the accuracy of subacromial injections and to correlate accuracy with short term clinical outcome at 3 months. Sixty shoulders, which were diagnosed with impingement syndrome, were randomized to receive a subacromial injection of corticosteroids, local anesthetic, and contrast dye from 1 of 3 locations: anterolateral, lateral, or posterior. Accuracy was confirmed by 3 radiographic views of the shoulder, while clinical ratings were assessed by the UCLA shoulder score and a 10-point visual pain analog scale during the initial, post-injection, and 3-month visits. The overall accuracy was 70%, with no difference among the 3 portals. Accuracy was not related to body mass index. Furthermore, accurate injections did not significantly improve the UCLA score, pain scale, or patient satisfaction at 3 months. In contrast, accurate injections produced a positive Neer's impingement test more often (35/39 vs 9/16; P = .009). Overall, there was an improvement in the UCLA score (26.2-32.2; P < .001) and a decrease in the pain scale (7.2-3.43; P < .001) at 3-month follow-up. In conclusion, the accuracy of injection was 70%. Clinical improvement did not correlate with accuracy; however, accuracy did reliably produce a positive impingement test. This multimodal treatment plan did produce significant improvement in shoulder function and pain level in the short term.

AB - Corticosteroids are commonly used in the treatment of the impingement syndrome. Efficacy, as well as accurate placement, have been questioned. The purpose of this prospective, randomized study is to assess the accuracy of subacromial injections and to correlate accuracy with short term clinical outcome at 3 months. Sixty shoulders, which were diagnosed with impingement syndrome, were randomized to receive a subacromial injection of corticosteroids, local anesthetic, and contrast dye from 1 of 3 locations: anterolateral, lateral, or posterior. Accuracy was confirmed by 3 radiographic views of the shoulder, while clinical ratings were assessed by the UCLA shoulder score and a 10-point visual pain analog scale during the initial, post-injection, and 3-month visits. The overall accuracy was 70%, with no difference among the 3 portals. Accuracy was not related to body mass index. Furthermore, accurate injections did not significantly improve the UCLA score, pain scale, or patient satisfaction at 3 months. In contrast, accurate injections produced a positive Neer's impingement test more often (35/39 vs 9/16; P = .009). Overall, there was an improvement in the UCLA score (26.2-32.2; P < .001) and a decrease in the pain scale (7.2-3.43; P < .001) at 3-month follow-up. In conclusion, the accuracy of injection was 70%. Clinical improvement did not correlate with accuracy; however, accuracy did reliably produce a positive impingement test. This multimodal treatment plan did produce significant improvement in shoulder function and pain level in the short term.

UR - http://www.scopus.com/inward/record.url?scp=38049173316&partnerID=8YFLogxK

U2 - 10.1016/j.jse.2007.07.010

DO - 10.1016/j.jse.2007.07.010

M3 - Article

C2 - 18201659

AN - SCOPUS:38049173316

VL - 17

JO - Journal of Shoulder and Elbow Surgery

JF - Journal of Shoulder and Elbow Surgery

SN - 1058-2746

IS - 1 SUPPL.

ER -